Focus additional systems
Focus™ Frieze
System range
Size, mm
XL
2400x600
T24
Thickness 20
M110 M239
System and product description
For applications where a smooth continuous transition between the ceiling and the wall is needed. The frieze can be connected to the wall without any visible trims. The tiles are not demountable.

The system consists of Ecophon Focus frieze tiles and Ecophon Connect grid systems, with an approximate weight of 3 kg/m². The tiles are manufactured from high density glass wool. The visible surface has an Akutex™ FT coating and the back of the tile is covered with glass tissue. The edges are painted.

For best performance and system quality, use Ecophon Connect grid and accessories. The grid is manufactured from galvanized steel.
Acoustics
Acoustic:
αp Practical sound absorption coefficient
Focus_frieze_abs1 Frequency Hz
Sound Absorption: Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
Sound Insulation: Dn,f,w=24 dB according to ISO 140-9 and evaluation according to EN ISO 717-1. CAC=25 dB according to ASTM E 1414 and evaluation according to ASTM E 413.
Sound Privacy: AC(1.5)=190 according to ASTM E 1111 and E 1110.
Product Focus Frieze
o.d.s mm 200
absorption class A
NRC
SAA
αw
Technical properties
Accessibility: The tiles are not demountable.
Cleanability: Daily dusting and vacuum cleaning. Weekly wet wiping.
Visual appearance: White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd/(m²lx). Gloss < 1.
Influence of climate: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate: Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6 according to ISO 14644-1.
Environmental influence: Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety: The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Technical properties, Fire safety.
Country Standard Class
Europe EN 13501-1 A2-s1,d0
Mechanical properties: For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Max live load (N) Min load bearing capacity (N)
M110, 2400x600 0 160
M239, 2400x600 0 160
Installation: Installed according to system range which includes information regarding minimum overall depth of system.
We help you with technical solutions and answers to your questions about our products.
A new feature turns watching installation diagrams into a 3D experience! Add another dimension to watching our installation diagrams. With our latest innovation we let you twist and turn and view close-ups directly on your computer.
The new Acoustics features applied room acoustics for Office, Education and Healthcare premises. Here you can explore the individual segments, and by using the room selector you can read up on the specific needs and acoustic solutions for that particular room.
Tell a friend Close

Your friends name:
*
Your name:
*
Your message:



Close

Result