Focus additional systems
Focus™ Wing
System range
Size, mm
1200x200
T24
Thickness 50
Inst. Diagr. M143 M209
System and product description
Ecophon Focus Wing is installed as the perimeter of a floating ceiling used together with Ecophon Focus Ds or E. It is a system of wing-shaped absorbers for free hanging suspended ceilings.

The systems consist of Ecophon Focus Wing elements and Ecophon Connect grid systems, with an approximate weight of 1 kg/m. The elements are manufactured from high density glass wool utilizing the 3RD Technology and the surface has an Akutex™ FT coating. The edges are painted.

For best performance and system quality, use Ecophon Connect grid and accessories. The grid system is manufactured from galvanized steel. The system is patented in Sweden.
Acoustics
Acoustic: Ecophon Focus Wing is a perimeter component. As such it is absorbent, however, for acoustic data on the system - please see corresponding ceiling system (Focus Ds or Focus/Master E).
Technical properties
Accessibility: The tiles are not demountable.
Cleanability: Daily dusting and vacuum cleaning. Weekly wet wiping.
Visual appearance: White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd/(m²lx). Gloss < 1.
Influence of climate: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate: Certified by the Indoor Climate Labelling, emission class M1 for building materials and recommended by the Swedish Asthma and Allergy Association.
Environmental influence: Glass wool core utilizing 3RD Technology. Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety: The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182.
Country Standard Class
Europe EN 13501-1 A2-s1,d0
Mechanical properties: No additional live load is allowed.
Max live load (N) Min load bearing capacity (N)
M143, 1200x200 0 160
M209, 1200x200 0 -
Installation: Installed according to installation diagrams, installation guides and drawing aid. For information regarding minimum overall depth of system see quantity specification.