Choose country:
United States
Česká republika
Danmark
Deutschland & Österreich
Eesti
España
France
Italia
Nederland
Norge
Polska
Россия
Schweiz
Suomi
Sverige
United Kingdom & Ireland
www.ecophon.com
Search
Products
Solutions
References
Acoustics
Functional demands
Contact
About Ecophon
Career
SITEMAP
Focus
Focus™ A
Download pdf
Tell a friend
Print
E-tools
Maintenance Guide
System and product description
Installation
Acoustics
Technical properties
System range
Size, mm
XL
XL
XL
XL
600x600
1200x600
1200x1200
1600x600
1800x600
2000x600
2400x600
T15
•
•
•
T24
•
•
•
•
•
•
•
Thickness
20
20
20
20
20
20
20
Inst. Diagr.
M01
M01
M01
M16
M46
M16
M46
M16
M46
M16
M46
System and product description
For applications where a robust suspended ceiling system is required. Ecophon Focus A has an exposed grid system. Each tile is easily demountable.
The systems consist of Ecophon Focus A tiles and Ecophon Connect grid systems, with an approximate weight of 3 kg/m². The tiles are manufactured from high density glass wool utilizing the 3RD Technology. The visible surface has an Akutex™ FT coating and the back of the tile is covered with glass tissue. The edges are primed. The grid is manufactured from galvanized steel.
M01
M16
M46
M01
VIEW 3D
Download installation guide
IG Edge A system (Loadbridge)
(1.32 MB)
Drawing Aid
Transitions
Installations
Fixings
Search
See Quantity specification
Suspension with adjustable hanger and clip
Suspension with direct bracket
Quantity specification (excl. wastage)
Installation diagram (M01) for Ecophon Focus A
Size, mm
600x600
1200x600
1200x1200
1 Focus A
2,8/m²
1,4/m²
0,7/m²
2 Connect T24 or T15 Main runner, installed at 1200 mm centres (max. distance from wall 600 mm, can be extended up to 1200 mm if no live load between Main runner and wall).
0,9m/m²
0,9m/m²
0,9m/m²
3 Connect T24 or T15 Cross tee, L=1200 mm, installed at 600 mm centres
1,7m/m²
1,7m/m²
0,9m/m²
4 Connect T24 or T15 Cross tee, L=600 mm
0,9m/m²
-
-
5 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm)
0,7/m²
0,7/m²
0,7/m²
6 Connect Hanger clip
0,7/m²
0,7/m²
0,7/m²
7 For direct installation: Connect Direct bracket, installed at 1200 mm centres
0,7/m²
0,7/m²
0,7/m²
8 Connect Angle trim, fixed at 300 mm centres
as required
as required
as required
9 Connect Shadow-line trim, fixed at 300 mm centres
as required
as required
as required
Δ Min. overall depth of system, with Adjustable hanger: 100 mm, with Direct bracket: 50 mm
-
-
-
δ Min. demounting depth: 120 mm (130 mm with 1200x1200)
-
-
-
M16
VIEW 3D
Drawing Aid
Transitions
Installations
Fixings
Search
See Quantity specification
Quantity specification (excl. wastage)
Installation diagram (M16) for Ecophon Focus A XL in corridors
Size, mm
1600x600
1800x600
2000x600
2400x600
1 Focus A
1,05/m²
0,95/m²
0,85/m²
0,7/m²
2 Connect T24 Corridor profile, installed at 600 mm centres
1,05/m²
0,95/m²
0,85/m²
0,7/m²
3 Connect Angle trim, fixed at 200 mm centres
as required
as required
as required
as required
4 Connect Shadow-line trim, fixed at 200 mm centres
as required
as required
as required
as required
Δ Min. overall depth of system: 40 mm
-
-
-
-
δ Min. demounting depth: 65 mm
-
-
-
-
M46
VIEW 3D
Drawing Aid
Transitions
Installations
Fixings
Search
See Quantity specification
Suspension with adjustable hanger and clip
Quantity specification (excl. wastage)
Installation diagram (M46) for Ecophon Focus A XL
Size, mm
1600x600
1800x600
2000x600
2400x600
1 Focus A
1,05/m²
0,95/m²
0,85/m²
0,7/m²
2 Connect T24 Main runner, installed at 600 mm centres
1,7m/m²
1,7m/m²
1,7m/m²
1,7m/m²
3 Connect T24 Cross tee, L=600 mm
0,65m/m²
0,6m/m²
0,5m/m²
0,45m/m²
4 Connect Adjustable hanger, installed at 1500 mm centres (max. distance from wall 450 mm)
1,1/m²
1,1/m²
1,1/m²
1,1/m²
5 Connect Hanger clip
1,1/m²
1,1/m²
1,1/m²
1,1/m²
6 Connect Angle trim, fixed at 300 mm centres
as required
as required
as required
as required
7 Connect Shadow-line trim, fixed at 300 mm centres
as required
as required
as required
as required
Δ Min. overall depth of system: 100 mm
-
-
-
-
δ Min. demounting depth: 100 mm
-
-
-
-
Acoustics
Acoustic:
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
α
ρ
Practical sound absorption coefficient
Frequency Hz
—
Ecophon Focus A 200 mm o.d.s.
····
Ecophon Focus A 50 mm o.d.s.
o.d.s = overall depth of system
Product
Focus A
o.d.s mm
50
90
100
200
400
absorption class
B
A
A
A
αw
0,80
0,90
0,90
0,95
NRC
0,85
-
-
-
0,85
SAA
0,83
-
-
-
0,88
Sound Insulation:
Dn,f,w=20 dB according to EN ISO 10848-2 and evaluation according to EN ISO 717-1. CAC=21 dB according to ASTM E 1414 and evaluation according to ASTM E 413
Sound Privacy:
AC(1.5)=190 according to ASTM E 1111 and E 1110.
Technical properties
Accessibility:
The tiles are easily demountable. Minimum demounting depth according to installation diagrams.
Cleanability:
Daily dusting and vacuum cleaning. Weekly wet wiping.
Visual appearance:
White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd/(m²lx). Gloss < 1.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate:
Certified by the Indoor Climate Labelling, emission class M1 for building materials and recommended by the Swedish Asthma and Allergy Association.
Environmental influence:
Glass wool core utilizing 3RD Technology. Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety:
The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003.
Country
Standard
Class
Europe
EN 13501-1
A2-s1,d0
Mechanical properties:
See table about Max live load and Min load bearing capacity and Functional demands, Mechanical properties at www.ecophon.com.
Max live load (N)
Min load bearing capacity (N)
M01
, 600x600
50
160
M01
, 1200x600
50
160
M01
, 1200x1200
50
160
M16
, 1600x600
40
-
M16
, 1800x600
20
-
M16
, 2000x600
10
-
M16
, 2400x600
0
-
M46
, 1600x600
50
160
M46
, 1800x600
50
160
M46
, 2000x600
50
160
M46
, 2400x600
50
160
Installation:
Installed according to installation diagrams, installation guides and drawing aid. For information regarding minimum overall depth of system see quantity specification.
Contact us
We can help with technical solutions and answers to your questions about our products or room acoustics.
Read more
Connect Bridging
Connect Bridging is a simple solution for integration of lighting products, signs, smoke detectors etc. The weight of the installation will be transferred to the grid, and there will be no load on the tile.
Read more
3D CAD
A new feature turns watching installation diagrams into a 3D experience! Add another dimension to watching our installation diagrams. With our latest innovation we let you twist and turn and view close-ups directly on your computer.
Read more
It's new, it's fresh - it's the new Acoustics
The new Acoustics features applied room acoustics for Office, Education and Healthcare premises. Here you can explore the individual segments, and by using the room selector you can read up on the specific needs and acoustic solutions for that particular room.
Read more
Copyright © 2002-2013 Ecophon Group. All rights reserved.
Trademarks
Cookies
Disclaimer
Tell a friend
Close
Your friends name:
*
Your friends email:
*
Your name:
*
Your e-mail:
*
Your message:
Transitions
Installation
Fixing
Search
Category
Subcategory
Detail list
Previous image
Next image
Type
Name
Description
Product
Sketch
Result
Previous image
Next image
Close