Hygiene Advance™ Baffle C3
Download pdf
Tell a friend
Print
E-tools
Maintenance Guide
System and product description
Installation
Acoustics
Technical properties
System range
Size, mm
1200x600
T24
•
Thickness
40
Inst. Diagr.
M259
M260
System and product description
Ecophon Hygiene Advance Baffle C3 is an open system with vertical baffles intended for use in environment where there is a high level of contamination, and where frequent cleaning is required. This system is used mainly in premises where it is not possible to install a wall to wall ceiling because of sprinkler systems, installations or skylights, etc. Examples of applications: areas with high levels of airborne grease, areas exposed to splatter from meat juices, fruit juices or other liquids.
The system consists of Ecophon Hygiene Advance Baffles, which have a core of high density glass wool encapsulated in a smooth high-performance film that is impervious to particles and water. The film is also dirt-repellent and resistant to most chemicals. The supporting structure is a corrosion protected exposed Connect T24 C3 grid of lacquered galvanised steel. The weight of the system is approximately 4 kg/m². The Ecophon Hygiene Advance Baffle C3 is a technical ceiling system which might have aesthetic variations that will not affect the functionality of the system.
M259
M260
M259
VIEW 3D
Download BIM file (Revit)
BIM Hygiene Advance Baffle
(1.45 MB)
Installation in rows
Detail of suspension
Suspension with adjustable hanger and clip
Quantity specification (excl. wastage)
Installation diagram (M259) for Ecophon Hygiene Advance Baffle C3 (in rows)
Size, mm
1200x600
1 Hygiene Advance Baffle
1,4/m²
2 Connect T24 Main runner C3, installed at 600 mm centres
1,7m/m²
3 Connect T24 Cross tee C3, L=600 mm, installed at 1800 mm centres
0,6m/m²
4 Connect Adjustable hanger C3
1,4/m²
5 Connect Hanger clip
1,4/m²
6 Connect Baffle clip C3
2,8/m²
M260
VIEW 3D
Download BIM file (Revit)
BIM Hygiene Advance Baffle
(1.45 MB)
Installation in rectangles
Detail of suspension
Suspension with adjustable hanger and clip
Quantity specification (excl. wastage)
Installation diagram (M260) for Ecophon Hygiene Advance Baffle C3 (in rectangles)
Size, mm
1200x600
1 Hygiene Advance Baffle
1,3/m²
2 Connect T24 Main runner C3, installed at 1250 mm centres
0,8m/m²
3 Connect T24 Cross tee C3, L=1250 mm, installed at 1300 mm centres
0,8m/m²
4 Connect Adjustable hanger C3
0,7/m²
5 Connect Hanger clip
0,7/m²
6 Connect Baffle clip C3
2,5/m²
Acoustics
Acoustic:
α
p
Practical sound absorption coefficient
Frequency, Hz
—
Ecophon Hygiene Advance Baffle C3 in rectangles, with ~1,3 baffles per m² of ceiling area
····
Ecophon Hygiene Advance Baffle C3 in rows, c 600 mm, with ~1,4 baffles per m² of ceiling area
Sound Absorption:
Test results according to EN ISO 354:2003
NOTE: Results shown are not comparable with results according to older versions of this standard due to discrepancies in test method.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
Sound Insulation:
Not applicable
Sound Privacy:
Not applicable
Product
in rows
in rectangles
o.d.s mm
600
600
absorption class
D
C
αw
0,55
0,60
NRC
1,0
1,0
SAA
1,0
1,0
Technical properties
Accessibility:
The tiles are demountable.
Cleanability:
Daily dusting, vacuum cleaning, manual wet cleaning, high-pressure washing and steam cleaning. Water temperature max. 70°C. Can withstand the use of common disinfecting chemicals.
Visual appearance:
White 141, nearest NCS colour sample S 1000-N, 73% light reflectance.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611). A higher temperature/moisture is permissible during washing as stated above. Microbiological growth class 0 according to ASTM G 21-96. The grid and accessories meet the demands of corrosion class C3 according to EN ISO 12944-2.
Indoor Climate:
Can be used in rooms classified as ISO class 4 according to ISO 14644-1.
Environmental influence:
Partly recyclable.
Fire safety:
The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182.
Country
Standard
Class
Europe
EN 13501-1
A2-s1,d0
Mechanical properties:
See table about Max live load and Min load bearing capacity and Functional demands, Mechanical properties at www.ecophon.com.
Max live load (N)
Min load bearing capacity (N)
M259
, 1200x600
0
160
M260
, 1200x600
0
160
Installation:
Installed according to installation diagrams, installation guides and drawing aid. Cut tiles must be sealed with Connect Hygiene Advance Tape. Penetrations must be sealed with a suitable sealant.
Contact us
We can help with technical solutions and answers to your questions about our products or room acoustics.
Read more
Hygiene Premises overview
Hygiene system overview & Quickguide - Room types
Download
Hygiene system brochure.pdf
3D CAD
A new feature turns watching installation diagrams into a 3D experience! Add another dimension to watching our installation diagrams. With our latest innovation we let you twist and turn and view close-ups directly on your computer.
Read more
Connect
Combine your Ecophon absorber with Connect grids, profiles and accessories for a complete ceiling solution.
Connect™
Copyright © 2002-2013 Ecophon Group. All rights reserved.
Trademarks
Cookies
Disclaimer
Tell a friend
Close
Your friends name:
*
Your friends email:
*
Your name:
*
Your e-mail:
*
Your message:
Transitions
Installation
Fixing
Search
Category
Subcategory
Detail list
Previous image
Next image
Type
Name
Description
Product
Sketch
Result
Previous image
Next image
Close