Hygiene
Hygiene Meditec™ E C1
System range
Size, mm
600x600 1200x600
T24
Thickness 15 15
M256 M256
System and product description
Ecophon Hygiene Meditec E C1 is a wall to wall, sound-absorbing ceiling system intended for environments where disinfection and/or cleaning is required on a regular basis. This system is recommended for dry environments. It has a recessed visible grid and a tegular edge design, creating a ceiling with a shadow effect that accentuates each tile and partially conceals the grid system. The visible surface of each tile is 7 mm below the grid. Examples of applications: nursing and healthcare premises.

The system consists of Ecophon Meditec E tiles, which have a core of high density glass wool and a painted cleanable Akutex™ TH surface. The back of the tile is covered with glass tissue. The edges are painted. The supporting structure is an exposed Connect T24 grid of galvanised steel. The weight of the system is approximately 2,5 kg/m². The tiles should be secured to the grid with Connect Universal clips in order to withstand pressure during cleaning and to minimise dirt traps.
Acoustics
Acoustic:
αp Practical sound absorption coefficient
Ecophon Hygiene Meditec E C1 abs1 Frequency, Hz
Ecophon Hygiene Meditec E C1, 200 mm o.d.s.
···· Ecophon Hygiene Meditec E C1, 60 mm o.d.s.
o.d.s= overall depth of system
Sound Absorption: Test results according to EN ISO 354.
Classification according to EN ISO 11654.
Sound Insulation: Not applicable.
Sound Privacy: Not applicable
Product Hygiene Meditec E C1
o.d.s mm 60 200 400
absorption class C A
NRC 0,9 - 0,85
SAA 0,87 - 0,84
αw
Technical properties
Accessibility: The tiles are demountable. Minimum demounting depth according to installation diagram. The tiles are secured using clips to allow for effective cleaning. The clips are easily removable from above the ceiling. An easy-to-open Connect Inspection hatch is available to simplify access to the ceiling void.
Cleanability: Daily dusting and vacuum cleaning. Weekly wet wiping. Steam cleaning four times/year. Can withstand the use of common disinfecting chemicals.
Visual appearance: White 010, nearest NCS colour sample S 0502-Y, 84% light reflectance.
Influence of climate: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611). A higher temperature/moisture is permissible during washing as stated above. The grid and accessories meet the demands of corrosion class C1 according to EN ISO 12944-2. For the microbiological resistance see Functional demands, Influence of climate.
Indoor Climate: Certified by the Indoor Climate Labelling, emission class M1 for building materials, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 5 according to ISO 14644-1.
Environmental influence: Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety: The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Technical properties, Fire safety.
Country Standard Class
Europe EN 13501-1 A2-s1,d0
Mechanical properties: For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Max live load (N) Min load bearing capacity (N)
M256, 600x600 50 160
M256, 1200x600 50 160
Installation: Installed according to system range. Cut panels must be sealed with Connect Edge sealant.