Hygiene
Hygiene Performance™ A C4
Download pdf
Tell a friend
Print
E-tools
Specifications
Maintenance manual
System and product description
Installation
Acoustics
Technical properties
System range
Size, mm
600x600
1200x600
T24
•
•
Thickness
20
20
M266
M266
System and product description
Ecophon Hygiene Performance A C4 is a unique wall to wall, sound absorbing ceiling system for use in demanding environments. All the suspension components, made of acid-proof stainless steel, are designed for areas with constantly high humidity and/or corrosive environments. Examples of applications: swimming halls, water parks and showers.
The system consists of Ecophon Hygiene Performance A tiles, which have a core of high density glass wool and a painted cleanable Akutex TH surface. The back of the tile is covered with glass tissue. The edges are primed. The supporting structure is an exposed Connect T24 C4 grid made of acid-proof high-performance austenitic stainless steel to avoid stress corrosion that can occur on ordinary stainless steel. The weight of the system is 3-4 kg/m². The tiles should be secured to the grid with Connect Hygiene clips in order to withstand pressure during cleaning and to minimise dirt traps. For access to the plenum a special Connect Democlip is used.
M266
M266
VIEW 3D
Drawing Aid
Transitions
Installations
Fixings
Search
See Quantity specification
Arrangement of clips
Cutting of Connect Hygiene clip 20 at the inspection tile
nhys2
Quantity specification (excl. wastage)
Installation diagram (M266) for Ecophon Hygiene Performance A C4
Size, mm
600x600
1200x600
1 Hygiene Performance A
2,8/m²
1,4/m²
2 Connect T24 Main runner C4, c1200
0,9m/m²
0,9m/m²
3 Connect T24 Cross tee C4, L=1200, c600
1,7m/m²
1,7m/m²
4 Connect T24 Cross tee C4, L=600
0,9m/m²
-
5 Connect Adjustable hanger C4, c1200, (max 600 mm distance from wall)
0,7/m²
0,7/m²
6 Connect Hygiene clip 20 C4
11/m²
7/m²
7 Connect Channel trim C4, fixed at c300 mm
as required
as required
8 Connect Demo clips 20 C4, (where access is needed)
as required
as required
9 Connect Fixing plate C4
0,7/m²
0,7/m²
10 Connect Anchor screw C4
0,7/m²
0,7/m²
11 Connect Installation screw C4
3,4/lm Channel trim C4
3,4/lm Channel trim C4
Δ Min. overall depth of system: 150 mm
-
-
δ Min. demounting depth: 150 mm
-
-
Acoustics
Acoustic:
α
p
Practical sound absorption coefficient
Frequency, Hz
—
Ecophon Hygiene Performance A C4, 20 mm, 200 mm o.d.s.
o.d.s= overall depth of system
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654.
Sound Insulation:
Not applicable.
Sound Privacy:
Not applicable
Product
Hygiene Performance A C4
o.d.s mm
200
400
absorption class
A
NRC
0,95
0,85
SAA
0,93
0,88
αw
Technical properties
Accessibility:
The tiles are demountable. Minimum demounting depth according to installation diagram. The tiles are secured using Connect Hygiene Clip to allow for effective cleaning. The clips are easily removable from above the ceiling. Connect Democlips 20 C4 are avalible to simplify access to the ceiling void.
Cleanability:
Daily dusting and vacuum cleaning. Weekly wet wiping. Steam cleaning four times/year and low pressure hosing twice a year. Can withstand the use of common disinfecting chemicals.
Visual appearance:
White 010, nearest NCS colour sample S 0502-Y, 84% light reflectance.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611). A higher temperature/moisture is permissible during washing as stated above. The grid and accessories meet the demands of corrosion class C4 according to EN ISO 12944-2. For the microbiological resistance see Functional demands, Influence of climate.
Indoor Climate:
Certified by the Indoor Climate Labelling, emission class M1 for building materials, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 5 according to ISO 14644-1.
Environmental influence:
Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety:
The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Technical properties, Fire safety.
Country
Standard
Class
Europe
EN 13501-1
A2-s1,d0
Mechanical properties:
For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Max live load (N)
Min load bearing capacity (N)
M266
, 600x600
50
160
M266
, 1200x600
50
160
Installation:
Installed according to system range. Cut panels must be sealed with Connect sealing tape using the Connect Tape applicator, or Connect Edge sealant. Penetrations must be sealed with a suitable sealant.
Contact Us
We help you with technical solutions and answers to your questions about our products.
Read more
Hygiene Premises overview
Hygiene system overview & Quickguide - Room types
Download
Hygiene system brochure.pdf
3D CAD
A new feature turns watching installation diagrams into a 3D experience! Add another dimension to watching our installation diagrams. With our latest innovation we let you twist and turn and view close-ups directly on your computer.
Read more
Copyright © 2002-2012 Ecophon Group. All rights reserved.
Trademarks
Cookies
Disclaimer
Tell a friend
Close
Your friends name:
*
Your friends email:
*
Your name:
*
Your e-mail:
*
Your message:
Transitions
Installation
Fixing
Search
Subcategory
Detail list
Previous image
Next image
Type
Name
Description
Product
Sketch
Result
Previous image
Next image
Close