Master™ Rigid E
Download pdf
Tell a friend
Print
E-tools
Maintenance Guide
System and product description
Installation
Acoustics
Technical properties
System range
Size, mm
600x600
1200x600
1200x1200
T24
•
•
•
Thickness
20
20
20
Inst. Diagr.
M317
M317
M317
System and product description
Suitable for classrooms or other premises where strict demands are made on good acoustics and speech intelligibility, and where demountability is vital. Ecophon Master Rigid E has a recessed visible grid and a tegular edge design, creating a ceiling with a shadow effect that accentuates each tile and partially conceales the grid system. The visible surface of each tile is 10 mm below the grid. Each tile is secured in the grid by clips (patent pending), but fully demountable.
The system consists of Ecophon Master Rigid E tiles, Ecophon Extra Bass and Ecophon Connect grid system, with an approximate weight of 3,5 kg/m². The tiles are manufactured from high density glass wool utilizing the 3RD Technology. The surface is a reinforced sandwich construction. The visible surface has an Akutex™ FT coating. The product is also available with a sound reflecting surface (gamma) with the same visual appearance. The back of the tile is covered with glass tissue. The edges are painted.
Ecophon Extra Bass is used to improve sound absorption in the low frequency range, and is installed on top of the suspended ceiling. For best performance and system quality, use Ecophon Connect grid and accessories. The grid is manufactured from galvanized steel.
M317
M317
VIEW 3D
Download installation guide
IG317 Master Rigid E
(2.14 MB)
Drawing Aid
Transitions
Fixings
Search
See Quantity specification
Connect Hold down clip E (patent pending)
Connect Demounting tool
Cutting tool E
Quantity specification (excl. wastage)
Installation diagram (M317) for Ecophon Master Rigid E
Size, mm
600x600
1200x600
1200x1200
1 Master Rigid E
2,8/m²
1,4/m²
0,7/m²
2 Connect T24 Main runner, installed at 1200 mm centres (max. distance from wall 600 mm, can be extended up to 1200 mm if no live load between Main runner and wall).
0,9m/m²
0,9m/m²
0,9m/m²
3 Connect T24 Cross tee, L=1200 mm, installed at 600 mm centres
1,7m/m²
1,7m/m²
0,9m/m²
4 Connect T24 Cross tee, L=600 mm
0,9m/m²
-
-
5 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm)
0,7/m²
0,7/m²
0,7/m²
6 Connect Hanger clip
0,7/m²
0,7/m²
0,7/m²
7 Connect Hold down clip E
2pcs/panel
2pcs/panel
2pcs/panel
8 Connect Channel trim, fixed at c300 mm (1200x1200, c200 mm)
as required
as required
as required
9 For direct installation: Connect Direct bracket, installed at 1200 mm centres
0,7/m²
0,7/m²
0,7/m²
10 Extra Bass (1200x600x50 mm)
0,6/m²
0,6/m²
0,6/m²
Δ Min. overall depth of system: 110 mm
-
-
-
δ Min. demounting depth: 120 mm, (170 mm incl. Ecophon Extra Bass)
-
-
-
Acoustics
Acoustic:
α
ρ
Practical sound absorption coefficient
Frequency Hz
—
Ecophon Master Rigid E 200 mm o.d.s.
---
Ecophon Master Rigid E/gamma 200 mm o.d.s.
····
Ecophon Master Rigid E + Ecophon Extra Bass 200 mm o.d.s.
o.d.s. = overall depth of system
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654.
Sound Insulation:
Not applicable
Sound Privacy:
Not applicable
Product
Master Rigid E
Master Rigid E +Extra Bass
Master Rigid E /gamma
o.d.s mm
200
200
200
absorption class
A
A
D
αw
0,95
0,95
0,30
Technical properties
Accessibility:
The tiles are secured in the grid, but demountable. Minimum demounting depth according to installation diagrams.
Cleanability:
Daily dusting and vacuum cleaning. Weekly wet wiping.
Visual appearance:
White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd/(m²lx). Gloss < 1.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate:
Certified by the Indoor Climate Labelling, emission class M1 for building materials and recommended by the Swedish Asthma and Allergy Association.
Environmental influence:
Glass wool core utilizing 3RD Technology. Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety:
The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003.
Country
Standard
Class
Europe
EN 13501-1
A2-s1,d0
Mechanical properties:
See table about Max live load and Min load bearing capacity and Functional demands, Mechanical properties at www.ecophon.com.
Max live load (N)
Min load bearing capacity (N)
M317
, 600x600
50
160
M317
, 1200x600
50
160
M317
, 1200x1200
50
160
Installation:
Installed according to installation diagrams, installation guides and drawing aid. For information regarding minimum overall depth of system see quantity specification.
Product information
Ecophon Extra Bass
Akutex™ FT
This smooth and attractive surface is available on several Ecophon ceiling tiles. We also offer a reinforced version on our Master Rigid systems.
Read more
Ecophon Master Rigid - because every classroom needs optimised acoustics
Studies have found a link between the sound environment in classrooms and students' performance. Find out how our flexible Master Rigid systems can be adapted to suit your classroom needs.
Read more
Support sound teaching and learning
School acoustics influence teaching, learning and behaviour in learning environments.
Read more
Contact a specialist
Get acoustic advice for YOUR specific building project. Contact Ecophon's education specialists for more information.
Read more
Copyright © 2002-2013 Ecophon Group. All rights reserved.
Trademarks
Cookies
Disclaimer
Tell a friend
Close
Your friends name:
*
Your friends email:
*
Your name:
*
Your e-mail:
*
Your message:
Transitions
Installation
Fixing
Search
Category
Subcategory
Detail list
Previous image
Next image
Type
Name
Description
Product
Sketch
Result
Previous image
Next image
Close