Ecophon Focus™ F

For applications requiring a ceiling which is mechanically secured to the structural soffit. Ecophon Focus F is installed directly to an existing plaster ceiling, boarding, battens or concrete, creating a ceiling with a smooth appearance. The bevelled edges create a narrow groove between each tile. The tiles are not demountable.
SYSTEM RANGE
Size, mm
600
X
600

1200
X
600
Screw
Thickness 20 20
Inst. diagr. m15 m15

The tiles are manufactured from high density glass wool. The visible surface has an Akutex FT coating and the back of the tile is covered with glass tissue. The edges are reinforced and painted. The weight is approximately 2,5 kg/m².

SOUND ABSORPTION: Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
SOUND INSULATION: Not applicable.
SOUND PRIVACY: Not applicable.

αp Practical sound absorption coefficient
<em>α</em><sub>p</sub> Practical sound absorption coefficient
Frequency, Hz
···· Ecophon Focus F 20 mm o.d.s.
--- Ecophon Focus F 40 mm o.d.s.
Ecophon Focus F 430 mm o.d.s. including 385 mm thermal insulation.
o.d.s = overall depth of system

Product Focus F
O.d.s. mm 20 40 430
Absorption class C C A
NRC 0.75    
SAA 0.77    

Focus F tile
Section of Focus F system
Focus F system
Focus F is installed by screw fixing
ACCESSIBILITY: The tiles are not demountable.
CLEANABILITY: Daily dusting and vacuum cleaning. Weekly wet cleaning.
LIGHT EFFICIENCY: White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection).
INFLUENCE OF CLIMATE: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
INDOOR CLIMATE: Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
ENVIRONMENTAL INFLUENCE: Granted the Nordic Swan eco-label. Fully recyclable.
FIRE SAFETY: Reaction-to-fire classifications.
Country Standard Class
UK BS 476 Parts 6&7 Class 0
Europe EN 13501-1 A2-s1,d0
The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Functional demands, Fire safety.
MECHANICAL PROPERTIES: Additional live load has to be secured to the soffit.
Inst. diagr., Size (mm) Max live load (N) Min load bearing capacity (N)
m15, 1200x600 -
m15, 600x600 -
INSTALLATION: Installed according to installation diagram M15, which includes information regarding minimum overall depth of system. For larger areas (>50m2) it can be more cost efficient to make the direct fixed installation with Focus C and Z-profiles according to M109. Displaced joints (brick pattern) will facilitate the alignment of the joints.
Installation Guides (pdf)
Size, mm
600
X
600

1200
X
600
Installation Guide IG 1008
IG 1006
IG 1008
IG 1006
www.ecophon.com, CADsupport, Product selector, Specification, Maintenance manual
 To top
Quantity specification (excl. wastage)
Installation diagram (M15) for Focus F
Size, mm
600x600 1200x600
Focus F 2.8/m² 1.4/m²
1 Connect Direct fixing plate F 0149, installed at 600 mm centres (for use in concrete) 2.8/m² 2.8/m²
2 Connect Anchor screw 4000, installed at 600 mm centres (for use in concrete) 2.8/m² 2.8/m²
3 Connect Installation screw MVL, installed at 200 mm centres (for use in plasterboard or timber) 8.3/m² 7/m²
4 Connect Spline F 0160, L=600 mm. Must be used in Sweden, Denmark, Norway and Finland at fireclass "Tändskyddande beklädnad" 2.8/m² 1.4/m²
5 Connect Spline 0219, L=150 mm 2.8/m² 1.4/m²
6 Connect Wall spring spacer 0087 1 per panel in the last row 1 per panel in the last row
7 Connect Angle trim, fixed at 300 mm centres as required as required
8 For use when installing floating ceilings: Connect Wood trim 2561, L=2500 mm, fixed at 500 mm centres as required as required