System and product description
Installation
Acoustics
Technical properties
System range
Size, mm
600x600
1200x600
1200x1200
T15
•
•
•
T24
•
•
•
Thickness
15
15
15
M118
M237
M118
M118
System and product description
For applications where a standard suspended ceiling system is required, but where strict functional requirements are needed. Ecophon Gedina A has an exposed grid. Each tile is easily demountable. The system consists of Ecophon Gedina A tiles and Ecophon Connect grid systems, with an approximate weight of 2,5 kg/m². The tiles are manufactured from high density glass wool. The visible surface has an Akutex™ T coating and the back of the tile is covered with glass tissue. Ecophon Gedina A can be supplied with primed edges or natural edges. For best performance and system quality, use Ecophon Connect grid and accessories. The grid is manufactured from galvanized steel.
M118
M237
M118
VIEW 3D
Cad Support
Transitions
Installations
Fixings
Search
Suspension with adjustable hanger and clip
Suspension with direct bracket
Quantity specification (excl. wastage)
Installation diagram (M118) for Gedina A
Size, mm
600x600
1200x600
1200x1200
1 Gedina A
2,8/m²
1,4/m²
0,7/m²
2 Connect T24 or T15 Main runner, installed at 1200 mm centres
0,9m/m²
0,9m/m²
0,9m/m²
3 Connect T24 or T15 Cross tee, L=1200 mm, installed at 600 mm centres
1,7m/m²
1,7m/m²
0,9m/m²
4 Connect T24 or T15 Cross tee, L=600 mm
0,9m/m²
-
-
5 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm)
0,7/m²
0,7/m²
0,7/m²
6 Connect Hanger clip
0,7/m²
0,7/m²
0,7/m²
7 For direct installation: Connect Direct bracket, installed at 1200 mm centres
0,7/m²
0,7/m²
0,7/m²
8 Connect Angle trim, fixed at 300 mm centres
as required
as required
as required
9 Connect Shadow-line trim, fixed at 300 mm centres
as required
as required
as required
Δ Min. overall depth of system, with Adjustable hanger: 100 mm, with Direct bracket: 50 mm
-
-
-
δ Min. demounting depth: 120 mm (130 mm with 1200x1200)
-
-
-
M237
VIEW 3D
Cad Support
Transitions
Installations
Fixings
Search
Straight cut, panel resting on wall trim
Quantity specification (excl. wastage)
Size, mm
600x600
1 Ecophon Gedina A
2,8/m²
2 Connect T24 Main runner, installed at 1800 mm centres
0,56m/m²
3 Connect T24 Cross tee, L=1800 mm
1,7m/m²
4 Connect T24 Cross tee, L=600 mm centres
1,1m/m²
5 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm)
0,46/m²
6 Connect Hanger clip
0,46/m²
7 Connect Angle trim, fixed at 300 mm centres
as required
8 Alt. Connect Shadow-line trim, fixed c300
as required
δ Min. demounting depth: 120 mm
-
Δ Min. overall depth of system, with Adjustable hanger: 100 mm, with Direct bracket: 50 mm
-
Acoustics
Acoustic:
αp Practical sound absorption coefficient
Frequency Hz
— Ecophon Gedina A 200 mm o.d.s.
--- Ecophon Gedina A 50 mm o.d.s.
o.d.s = overall depth of system
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
Sound Insulation:
Dn,c,w=18 dB according to ISO 140-9 and evaluation according to EN ISO 717-1. CAC=19 dB according to ASTM E 1414 and evaluation according to ASTM E 413.
Sound Privacy:
AC(1.5)=190 according to ASTM E 1111 and E 1110.
Product
Gedina A
o.d.s mm
50
80
90
200
absorption class
C
B
A
A
NRC
SAA
Technical properties
Accessibility:
The tiles are easily demountable. Minimum demounting depth according to installation diagrams.
Cleanability:
Daily dusting and vacuum cleaning. Weekly wet wiping.
Visual appearance:
White 500, nearest NCS colour sample S 0500-N, 84% light reflectance (of which more than 99% is diffuse reflection)
Environmental influence:
Granted the Nordic Swan eco-label. Fully recyclable.
Indoor Climate:
Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6 according to ISO 14644-1.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Fire safety:
The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Functional demands, Fire safety.
Country
Standard
Class
Europe
EN 13501-1
A2-s1,d0
Mechanical properties:
For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Max live load (N)
Min load bearing capacity (N)
M118
, 600x600
50
160
M118
, 1200x600
50
160
M118
, 1200x1200
50
160
M237
, 600x600
20
160
Installation:
Installed according to system range which includes information regarding minimum overall depth of system.
Ecophon Gedina with Akutex™ T surface now in white 500
Akutex™ T is available on the Gedina ceiling tiles. This well-tried painted surface in combination with the glasswool core provides optimal sound absorption.
Read more
Copyright © 2002-2010 Ecophon Group. All rights reserved.
Trademarks
Cookies
Disclaimer
Tell a friend
Close
Your friends name:
*
Your friends email:
*
Your name:
*
Your e-mail:
*
Your message:
Transitions
Installation
Fixing
Search
Subcategory
Detail list
Previous image
Next image
Type
Name
Description
Product
Sketch
Result
Previous image
Next image
Close