System and product description
Ecophon Hygiene Foodtec A C3 is a sound absorbing ceiling system intended for environments where there is risk of contamination, and where frequent cleaning is required. This system is recommended where humidity levels are occasionally high. Examples of applications: the food and beverage industries, restaurants and catering kitchens.

The system consists of Ecophon Hygiene Foodtec A tiles, which have a core of high density glass wool and a painted stain protected Akutex HS surface. The back and the edges are painted. The tile is designed to be demounted and cleaned on a regular basis. The supporting structure is a corrosion protected exposed Connect T24 C3 grid of lacquered galvanised steel. The weight of the system is 3-4 kg/m2. The tiles should be secured to the grid with Connect Hygiene clips in order to withstand pressure during cleaning and to minimise dirt traps.
Acoustics
Acoustic:
Sound Absorption: Test results according to EN ISO 354.
Classification according to EN ISO 11654.
Sound Insulation: Not applicable.
Sound Privacy: Not applicable
Product Hygiene Foodtec A C3, 20 mm thick Hygiene Foodtec A C3, 40 mm thick
o.d.s mm 200 200
absorption class A A
αw
Technical properties
Accessibility: The tiles are demountable. Minimum demounting depth according to installation diagram. The tiles are secured using Hygiene Clip 20 to allow for effective in-situ cleaning. The clips are easily removable from above the ceiling. A tightly sealed, easy-to-open Hygiene Inspection hatch is available to simplify access to the ceiling void.
Cleanability: Daily dusting and vacuum cleaning. Weekly wet cleaning on all surfaces and high-pressure washing twice a year. Can withstand the use of common disinfecting chemicals.
Visual appearance: White 500, nearest NCS colour sample S 0500-N, 84% light reflectance.
Influence of climate: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611). A higher temperature/moisture is permissible during washing as stated above.
Indoor Climate: Certified by the Indoor Climate Labelling, emission class M1 for building materials, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 5 according to ISO 14644-1.
Environmental influence: Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety: The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Functional demands, Fire safety.
Country Standard Class
Europe EN 13501-1 A2-s1,d0
Mechanical properties: For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Max live load (N) Min load bearing capacity (N)
M249, 600x600 50 160
M249, 1200x600 50 160
Installation: Installed according to system range. Cut panels must be sealed with Connect sealing tape using the Connect Tape applicator, or Connect Edge sealant. Penetrations must be sealed with a suitable sealant.
Watch this video to hear and see for yourself the difference good acoustic treatment has made to the staff and students at an English school.
Please contact us for prices & availability on 01256 850977
CPD subjects include Acoustic Comfort, Design Solutions, Education, Healthcare and Clean Industry. To book a CPD seminar please call 01256 850977 and ask for an Architectural Advisor.
Ecophon turns installation diagrams into a 3D experience! With our latest innovation we give you the possibility to twist and turn and view installation diagrams as close ups directly on your computer. You can find them under the installation tab, in products.
Ecophon - Proud sponsors of AJ100
Tell a friend Close

Your friends name:
*
Your name:
*
Your message:



Close

Result