Hygiene
Hygiene Performance™ A C4
System range
Size, mm
600x600 1200x600
T24
Thickness 20 20
M266 M266
System and product description
Ecophon Hygiene Performance A C4 is a unique wall to wall, sound absorbing ceiling system for use in demanding environments. All the suspension components, made of acid-proof stainless steel, are designed for areas with constantly high humidity and/or corrosive environments. Examples of applications: swimming halls, water parks and showers.

The system consists of Ecophon Hygiene Performance A tiles, which have a core of high density glass wool and a painted cleanable Akutex TH surface. The back of the tile is covered with glass tissue. The edges are primed. The supporting structure is an exposed Connect T24 C4 grid made of acid-proof high-performance austenitic stainless steel to avoid stress corrosion that can occur on ordinary stainless steel. The weight of the system is 3-4 kg/m². The tiles should be secured to the grid with Connect Hygiene clips in order to withstand pressure during cleaning and to minimise dirt traps. For access to the plenum a special Connect Democlip is used.
Acoustics
Acoustic:
Sound Absorption: Test results according to EN ISO 354.
Classification according to EN ISO 11654.
Sound Insulation: Not applicable.
Sound Privacy: Not applicable
Product Hygiene Performance A C4
o.d.s mm 200
absorption class A
NRC
SAA
αw
Technical properties
Accessibility:
Cleanability: Daily dusting and vacuum cleaning. Weekly wet wiping. Steam cleaning four times/year and low pressure hosing twice a year. Can withstand the use of common disinfecting chemicals.
Visual appearance: White 010, nearest NCS colour sample S 0502-Y, 84% light reflectance.
Influence of climate:
Indoor Climate: Certified by the Indoor Climate Labelling, emission class M1 for building materials, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 5 according to ISO 14644-1.
Environmental influence: Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety: The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Functional demands, Fire safety.
Country Standard Class
Europe EN 13501-1 A2-s1,d0
Mechanical properties: For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Max live load (N) Min load bearing capacity (N)
M266, 600x600 50 160
M266, 1200x600 50 160
Installation: Installed according to system range. Cut panels must be sealed with Connect sealing tape using the Connect Tape applicator, or Connect Edge sealant. Penetrations must be sealed with a suitable sealant.
Watch this video to hear and see for yourself the difference good acoustic treatment has made to the staff and students at an English school.
Please contact us for prices & availability on 01256 850977
CPD subjects include Acoustic Comfort, Design Solutions, Education, Healthcare and Clean Industry. To book a CPD seminar please call 01256 850977 and ask for an Architectural Advisor.
Ecophon turns installation diagrams into a 3D experience! With our latest innovation we give you the possibility to twist and turn and view installation diagrams as close ups directly on your computer. You can find them under the installation tab, in products.
Ecophon - Proud sponsors of AJ100
Tell a friend Close

Your friends name:
*
Your name:
*
Your message:



Close

Result